A potentiostat differs from a simple power supply in one fundamental way: it controls the potential of an electrode relative to a reference, rather than simply applying a fixed voltage across two terminals. A power supply sets the voltage between its output terminals regardless of what happens inside the cell. A potentiostat continuously measures the electrode potential and adjusts its output in real time to maintain the target value. The sections below address the most common technical questions that arise when choosing between these instruments for electrochemical testing and battery research.
What can a potentiostat do that a power supply cannot?
A potentiostat uses a three-electrode configuration to independently control the potential of a working electrode against a stable reference electrode, while measuring the current that flows through a counter electrode. A simple power supply applies a voltage between two terminals and cannot distinguish between the potential at each electrode, the resistive drop across the electrolyte, or changes in electrode kinetics during a measurement.
In practice, this means a potentiostat can:
- Hold the working electrode at a precise potential regardless of changes in electrolyte resistance or electrode impedance
- Operate in both potentiostatic mode (controlled voltage) and galvanostatic mode (controlled current)
- Measure small, rapidly changing currents with high resolution
- Apply and analyse alternating current (AC) perturbations for electrochemical impedance spectroscopy (EIS)
- Record transient responses such as cyclic voltammetry (CV) sweeps and chronoamperometry
A power supply can deliver a stable direct current (DC) voltage or current, which is sufficient for some bulk electrolysis tasks, but it provides no feedback from the electrode interface and cannot perform diagnostic measurements. For any experiment where the electrode potential must be known and controlled accurately, a power supply is not an adequate substitute.
How does a potentiostat control voltage in an electrochemical cell?
A potentiostat controls voltage in an electrochemical cell through a feedback loop involving three electrodes: the working electrode, the reference electrode, and the counter electrode. The instrument continuously compares the measured potential of the working electrode against the reference with the user-defined setpoint, then drives current through the counter electrode to eliminate any difference. This process repeats at high frequency, maintaining the target potential even as the cell’s internal conditions change.
The reference electrode is central to this mechanism. Because it maintains a stable, known electrochemical potential, it gives the potentiostat a fixed benchmark. The instrument’s high-impedance input reads the working-to-reference potential without drawing current through the reference, preserving its stability. The counter electrode carries all the compensating current, protecting both the working and reference electrodes from unintended perturbation.
This architecture means that even as the electrolyte resistance changes with temperature or concentration, or as the electrode surface evolves during a reaction, the working electrode potential remains controlled. A two-terminal power supply has no equivalent mechanism and cannot compensate for these variables.
Why does electrode potential matter more than applied voltage in battery research?
In battery research, electrode potential matters more than applied voltage because the electrochemical reactions at an electrode surface are governed by the local potential at that interface, not by the total voltage applied across the cell. Reaction thermodynamics, reaction kinetics, and the stability of electrode materials all depend on the electrode potential relative to a defined reference. Applied voltage includes contributions from electrolyte resistance, contact resistances, and counter-electrode polarisation, none of which reflect the true driving force at the working electrode.
For battery materials researchers, this distinction has direct experimental consequences. When characterising a new cathode material, for example, the specific capacity in mAh/g is measured as a function of electrode potential. If only the terminal voltage of the full cell is recorded, the individual contributions of the anode and cathode cannot be separated, and any overpotential arising from electrolyte resistance will be misattributed to the material itself.
Half-cell measurements, which use a lithium metal reference and counter electrode, are a standard approach precisely because they isolate the potential response of a single electrode. This is only possible with a potentiostat. The data produced, including the precise onset potentials for phase transitions or solid electrolyte interphase (SEI) layer formation, informs material development in ways that full-cell terminal voltage measurements cannot.
What is the difference between potentiostatic and galvanostatic mode?
In potentiostatic mode, the instrument holds the working electrode at a fixed potential and measures the resulting current. In galvanostatic mode, the instrument applies a fixed current and measures the resulting potential. These two modes address different experimental questions and are both standard features of a modern potentiostat-galvanostat (PStat/GStat) instrument.
Potentiostatic mode is used when the researcher needs to control the thermodynamic driving force precisely, for example during cyclic voltammetry, linear sweep voltammetry, or potentiostatic electrochemical impedance spectroscopy. It reveals how current responds to potential, which is directly related to reaction kinetics and diffusion processes.
Galvanostatic mode is used when a defined charge or discharge rate is required, which is the standard condition for measuring specific capacity and coulombic efficiency in battery cycling experiments. Applying a current equivalent to a given C-rate and recording the potential response over time produces the charge-discharge profiles that characterise a material’s electrochemical performance.
Many experiments combine both modes. A galvanostatic intermittent titration technique (GITT) measurement, for example, alternates between galvanostatic pulses and potentiostatic relaxation periods to separate kinetic and thermodynamic contributions to the electrode response. This kind of protocol requires an instrument with accurate, low-noise performance in both modes.
Can a potentiostat perform electrochemical impedance spectroscopy?
Yes. A potentiostat with EIS capability applies a small sinusoidal AC perturbation to the working electrode, either as a voltage or current signal, across a defined range of frequencies, and measures the amplitude and phase of the resulting response. From this data, the impedance of the electrochemical cell is calculated as a function of frequency, producing a spectrum that can be analysed to separate contributions from different physical processes.
EIS is one of the most information-rich techniques available to battery researchers. A single impedance spectrum can reveal:
- Electrolyte resistance (from the high-frequency intercept on the real axis)
- SEI layer resistance and capacitance (from a semicircle in the mid-frequency range)
- Charge-transfer resistance at the electrode-electrolyte interface
- Solid-state diffusion processes within the electrode material (from a low-frequency Warburg element)
A simple power supply cannot perform EIS. The technique requires precise generation of small-amplitude sinusoidal signals across a wide frequency range, typically from several hundred kilohertz down to millihertz, and accurate measurement of the phase relationship between voltage and current. This demands specialised analogue and digital circuitry that is not present in a standard DC power supply.
Instruments such as the PAT-Tester-i-16 integrate PStat/GStat and EIS capabilities across multiple channels, allowing researchers to run impedance measurements alongside standard cycling protocols without changing equipment.
When should battery researchers use a potentiostat instead of a battery cycler?
Battery researchers should use a potentiostat when the experiment requires three-electrode measurements, EIS, voltammetric techniques, or precise control of individual electrode potentials. A battery cycler is optimised for long-duration galvanostatic cycling of full cells with defined voltage limits, but it typically operates in a two-electrode configuration and lacks the diagnostic measurement modes that a potentiostat provides.
Situations where a potentiostat is the appropriate instrument include:
- Half-cell characterisation of new electrode materials using a lithium reference electrode
- Cyclic voltammetry to identify redox processes and phase transitions
- EIS measurements to quantify SEI resistance, charge-transfer kinetics, or solid-state diffusion
- Operando measurements where electrode potential must be tracked independently of counter-electrode behaviour
- Any experiment requiring a controlled overpotential at a defined current density (mA/cm²)
A battery cycler is more appropriate for long-term capacity retention studies, rate capability tests across many cycles, and formation protocols on finished cells, where the primary output is coulombic efficiency and capacity fade over hundreds or thousands of cycles rather than mechanistic electrochemical data.
In many research workflows, both instruments are used in sequence: a potentiostat characterises the material at the half-cell level, and a battery tester evaluates performance at the full-cell level. The two instruments are complementary rather than interchangeable.
How EL-Cell GmbH supports potentiostat-based battery research
We design our PAT Series instruments to address the full range of electrochemical measurements described in this article, within a single, interoperable research ecosystem. Our instruments are not isolated components but part of a complete platform that includes test cells, software, and lab tooling developed to work together.
- Multi-mode measurement: The PAT-Tester-i-16 provides PStat/GStat and EIS functionality across up to 16 independent channels, with a temperature-controlled cell chamber integrated into the same unit. Researchers can run impedance spectroscopy, cyclic voltammetry, and galvanostatic cycling on separate cells simultaneously.
- Three-electrode cell compatibility: Our PAT-Cell range is designed for half-cell and full-cell configurations, including reference electrode ports where required, so the three-electrode measurements that define potentiostat use are fully supported at the cell hardware level.
- Complete experimental setup from a single source: We supply the tester, the test cell, the consumables, and the software, removing compatibility concerns and reducing procurement complexity for research labs.
- In-house testing services: We operate our own electrochemical laboratory and can perform test measurements for customers who need results before committing to equipment purchase or who require outsourced measurement capacity.
If you are evaluating whether a potentiostat-based instrument is the right fit for your research workflow, we are glad to discuss your specific experimental requirements. Contact us to speak with one of our application specialists.