ECC1-00-0420-R
Pre-assembled insulation sleeve for the PAT-Core,
3-layered, with reference electrode and separator

Product Overview
ECC1-00-0420-R: Insulation sleeve (PP), modified LFP ref, GF/A separator, 260 µm, 3-layer
- Insulation sleeve, 3-layered, with reference electrode and separator
- Reference electrode: Celgard QT17P2HX separator, single-sided coated with modified LFP reference on stainless steel mesh
- Separator: two layers of glass fibre (GF/A), 260 µm
- Temperature range -20°C to 70°C
- For PAT-Core
Further information on the product features:
This insulation sleeve setup ensures a uniform current density distribution. In addition, the reference electrode is already adjusted to a stable reference potential through the use of chemically partially delithiated LFP and can therefore be used without any further preconditioning. Read more in our application note: Impedance simply achieved: Single electrode impedances at varying SOC in one go
Setup and Assembly

Sample assembly steps in a PAT-Cell:
Please note: The Lower Plunger Vario is required in this setup.
- Insert the 18.5 mm diameter GF/A separator at the bottom of the insulation sleeve.
- Place the cathode on the separator, active side facing the insulation sleeve.
- Insert the Lower Plunger Vario.
- Turn the insulation sleeve over and insert it into the PAT-Cell.
- Place the 18 mm diameter QT17P2HX separator coated with modified LFP on the mesh of the insulation sleeve, with the black LFP-coated side facing the mesh.
- Place the second 18.5 mm diameter GF/A separator on the exposed QT17 side.
- Add electrolyte.
- Place the Upper Plunger on top.
- Insert a sealing ring into the cell base then close the PAT-Cell.
Compatibility
| PAT series test cell | Compatible |
| PAT-Cell | |
| PAT-Cell-Press | |
| PAT-Cell-Gas | |
| PAT-Cell-HT | * |
| PAT-Cell-Twin-Ref | |
| PAT-Cell-Force | |
| PAT-Cell-Solid |
*Please note the operational temperature range of max. 70°C for the PP sleeve, if using the product inside the PAT-Cell-HT.